Skip to main content

Central venous pressure








Central venous pressure


From Wikipedia, the free encyclopedia

Jump to navigation
Jump to search


Central venous pressure (CVP) is the blood pressure in the venae cavae, near the right atrium of the heart. CVP reflects the amount of blood returning to the heart and the ability of the heart to pump the blood back into the arterial system. CVP is often a good approximation of right atrial pressure (RAP),[1] although the two terms are not identical, as a pressure differential can sometimes exist between the venae cavae and the right atrium. CVP and RAP can differ when arterial tone is altered. This can be graphically depicted as changes in the slope of the venous return plotted against right atrial pressure (where central venous pressure increases, but right atrial pressure stays the same; VR = CVP − RAP).


CVP has been, and often still is, used as a surrogate for preload, and changes in CVP in response to infusions of intravenous fluid have been used to predict volume-responsiveness (i.e. whether more fluid will improve cardiac output). However, there is increasing evidence that CVP, whether as an absolute value or in terms of changes in response to fluid, does not correlate with ventricular volume (i.e. preload) or volume-responsiveness, and so should not be used to guide intravenous fluid therapy.[2][3] Nevertheless, CVP monitoring is a useful tool to guide hemodynamic therapy.
The cardiopulmonary baroreflex responds to an increase in CVP by decreasing systemic vascular resistance while increasing heart rate and ventricular contractility in dogs.[4]




Contents





  • 1 Measurement


  • 2 Factors affecting CVP


  • 3 See also


  • 4 References


  • 5 External links




Measurement[edit]























SiteNormal
pressure range
(in mmHg)[5]
Central venous pressure3–8
Right ventricular pressuresystolic15–30
diastolic3–8
Pulmonary artery pressuresystolic15–30
diastolic4–12
Pulmonary vein/

Pulmonary capillary wedge pressure


2–15
Left ventricular pressuresystolic100–140
diastolic3–12

Normal CVP in patients can be measured from two points of reference:



  • Sternum: 0–14 cm H2O


  • Midaxillary line: 8–15 cm H2O

CVP can be measured by connecting the patient's central venous catheter to a special infusion set which is connected to a small diameter water column. If the water column is calibrated properly the height of the column indicates the CVP.


In most intensive care units, facilities are available to measure CVP continuously.


Normal values vary between 4 and 12 cmH2O.



Factors affecting CVP[edit]


Factors that increase CVP include:


  • Cardiac tamponade

  • Decreased cardiac output

  • Forced exhalation

  • Heart failure

  • Hypervolemia


  • Mechanical ventilation and the application of positive end-expiratory pressure (PEEP)

  • Pleural effusion

  • Pulmonary embolism

  • Pulmonary hypertension

  • Tension pneumothorax

Factors that decrease CVP include:


  • Deep inhalation

  • Distributive shock

  • Hypovolemia


See also[edit]


  • Jugular venous pressure

  • Pulmonary capillary wedge pressure


References[edit]




  1. ^ "Central Venous Catheter Physiology". Archived from the original on 2008-08-21. Retrieved 2009-02-27..mw-parser-output cite.citationfont-style:inherit.mw-parser-output .citation qquotes:"""""""'""'".mw-parser-output .citation .cs1-lock-free abackground:url("//upload.wikimedia.org/wikipedia/commons/thumb/6/65/Lock-green.svg/9px-Lock-green.svg.png")no-repeat;background-position:right .1em center.mw-parser-output .citation .cs1-lock-limited a,.mw-parser-output .citation .cs1-lock-registration abackground:url("//upload.wikimedia.org/wikipedia/commons/thumb/d/d6/Lock-gray-alt-2.svg/9px-Lock-gray-alt-2.svg.png")no-repeat;background-position:right .1em center.mw-parser-output .citation .cs1-lock-subscription abackground:url("//upload.wikimedia.org/wikipedia/commons/thumb/a/aa/Lock-red-alt-2.svg/9px-Lock-red-alt-2.svg.png")no-repeat;background-position:right .1em center.mw-parser-output .cs1-subscription,.mw-parser-output .cs1-registrationcolor:#555.mw-parser-output .cs1-subscription span,.mw-parser-output .cs1-registration spanborder-bottom:1px dotted;cursor:help.mw-parser-output .cs1-ws-icon abackground:url("//upload.wikimedia.org/wikipedia/commons/thumb/4/4c/Wikisource-logo.svg/12px-Wikisource-logo.svg.png")no-repeat;background-position:right .1em center.mw-parser-output code.cs1-codecolor:inherit;background:inherit;border:inherit;padding:inherit.mw-parser-output .cs1-hidden-errordisplay:none;font-size:100%.mw-parser-output .cs1-visible-errorfont-size:100%.mw-parser-output .cs1-maintdisplay:none;color:#33aa33;margin-left:0.3em.mw-parser-output .cs1-subscription,.mw-parser-output .cs1-registration,.mw-parser-output .cs1-formatfont-size:95%.mw-parser-output .cs1-kern-left,.mw-parser-output .cs1-kern-wl-leftpadding-left:0.2em.mw-parser-output .cs1-kern-right,.mw-parser-output .cs1-kern-wl-rightpadding-right:0.2em


  2. ^ Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, et al. (2004). "Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects" (PDF). Crit Care Med. 32 (3). doi:10.1097/01.ccm.0000114996.68110.c9.


  3. ^ Marik P, Baram M, Vahid B (July 2008). "Does Central Venous Pressure Predict Fluid Responsiveness?" (PDF). Chest. 134 (1): 1351. doi:10.1378/chest.08-1846.


  4. ^ Sala-Mercado JA, Moslehpour M, Hammond RL, Ichinose M, Chen X, Evan S, O'Leary DS, Mukkamala R (June 2014). "Stimulation of the Cardiopulmonary Baroreflex Enhances Ventricular Contractility in Awake Dogs: A Mathematical Analysis Study". American Journal of Physiology. Regulatory, Integrative and Comparative Physiology. 307 (4): R455–R464. doi:10.1152/ajpregu.00510.2013. PMC 4137157.


  5. ^ Table 30-1 in: Trudie A Goers; Washington University School of Medicine Department of Surgery; Klingensmith, Mary E; Li Ern Chen; Sean C Glasgow (2008). The Washington manual of surgery. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins. ISBN 0-7817-7447-0.




External links[edit]



  • Venous function and central venous pressure: a physiologic story - a technical discussion of the more modern understanding of central venous pressure; this may well conflict with the sources below.

  • Central Venous Pressure Monitoring

  • Cardiovascular Physiology Concepts

  • Central Venous Pressure and Pulmonary Capillary Wedge Monitoring

  • Cardiovascular Physiology


  • Central+Venous+Pressure at the US National Library of Medicine Medical Subject Headings (MeSH)









Retrieved from "https://en.wikipedia.org/w/index.php?title=Central_venous_pressure&oldid=878099862"





Navigation menu


























(window.RLQ=window.RLQ||).push(function()mw.config.set("wgPageParseReport":"limitreport":"cputime":"0.204","walltime":"0.258","ppvisitednodes":"value":476,"limit":1000000,"ppgeneratednodes":"value":0,"limit":1500000,"postexpandincludesize":"value":42681,"limit":2097152,"templateargumentsize":"value":133,"limit":2097152,"expansiondepth":"value":7,"limit":40,"expensivefunctioncount":"value":2,"limit":500,"unstrip-depth":"value":1,"limit":20,"unstrip-size":"value":17204,"limit":5000000,"entityaccesscount":"value":2,"limit":400,"timingprofile":["100.00% 206.724 1 -total"," 82.74% 171.053 1 Template:Reflist"," 42.75% 88.382 1 Template:Cite_web"," 27.63% 57.117 3 Template:Cite_journal"," 10.91% 22.554 3 Template:Navbox"," 10.51% 21.720 1 Template:Cardiovascular_physiology"," 4.92% 10.178 1 Template:MeshName"," 3.35% 6.917 1 Template:Cite_book"," 1.69% 3.497 1 Template:Non-systemic_blood_pressures"," 1.53% 3.165 1 Template:Main_other"],"scribunto":"limitreport-timeusage":"value":"0.117","limit":"10.000","limitreport-memusage":"value":2634064,"limit":52428800,"cachereport":"origin":"mw1321","timestamp":"20190203020130","ttl":2073600,"transientcontent":false););"@context":"https://schema.org","@type":"Article","name":"Central venous pressure","url":"https://en.wikipedia.org/wiki/Central_venous_pressure","sameAs":"http://www.wikidata.org/entity/Q190402","mainEntity":"http://www.wikidata.org/entity/Q190402","author":"@type":"Organization","name":"Contributors to Wikimedia projects","publisher":"@type":"Organization","name":"Wikimedia Foundation, Inc.","logo":"@type":"ImageObject","url":"https://www.wikimedia.org/static/images/wmf-hor-googpub.png","datePublished":"2005-12-03T16:24:45Z","dateModified":"2019-01-13T00:53:24Z","headline":"blood pressure in the venae cavae, near the right atrium of the heart"(window.RLQ=window.RLQ||).push(function()mw.config.set("wgBackendResponseTime":128,"wgHostname":"mw1324"););

Popular posts from this blog

𛂒𛀶,𛀽𛀑𛂀𛃧𛂓𛀙𛃆𛃑𛃷𛂟𛁡𛀢𛀟𛁤𛂽𛁕𛁪𛂟𛂯,𛁞𛂧𛀴𛁄𛁠𛁼𛂿𛀤 𛂘,𛁺𛂾𛃭𛃭𛃵𛀺,𛂣𛃍𛂖𛃶 𛀸𛃀𛂖𛁶𛁏𛁚 𛂢𛂞 𛁰𛂆𛀔,𛁸𛀽𛁓𛃋𛂇𛃧𛀧𛃣𛂐𛃇,𛂂𛃻𛃲𛁬𛃞𛀧𛃃𛀅 𛂭𛁠𛁡𛃇𛀷𛃓𛁥,𛁙𛁘𛁞𛃸𛁸𛃣𛁜,𛂛,𛃿,𛁯𛂘𛂌𛃛𛁱𛃌𛂈𛂇 𛁊𛃲,𛀕𛃴𛀜 𛀶𛂆𛀶𛃟𛂉𛀣,𛂐𛁞𛁾 𛁷𛂑𛁳𛂯𛀬𛃅,𛃶𛁼

Edmonton

Crossroads (UK TV series)